Relay Modules
Softstarters
DOLD softstarters ensure a soft and jerkless starting of your asynchronous motors. This reduces wearing and improves the service life of your motors and mechanical drive components. Application areas include:
- Machines with geared, belt and chain drives
- Conveyors, fans, pumps, compressors
- Wood working machines, centrifuges
- Cranes, travelling and slewing gear, elevators
- Easy installation by snapping on a top hat rail
- Space-saving by compact design with integrated bypass relay
- Improve safety by integrated temperature monitoring
- Improve setting flexibility by separate setting of starting time, locked-rotor torque and deceleration time
- More application flexibility, suited for a wide motor voltage range
- Take off load from the supply system by reduction of starting currents
Starting methods for motors are the starting current as well as the starting torque
To get this under control it is the best to reduce the clamp voltage of the motor.
The following procedures have been developed until now:
- starting transformer
- starting resistor 3-pole
- starting resistor 1-pole (KUSA- circuit)
- star- delta switch
Application areas of DOLD softstarters include:
- Centrifuges
- Wood working machines
- Cranes, travelling and slewing gear, elevators
- Machines with geared, belt and chain drives
Softstarters MINISTART, 1- | ||||||||
Function | f. three- motors, 400 V up to [kW] |
f. single- motors, 230 V up to [kW] |
Diverse signalling outputs |
Load voltage [V] |
Auxiliary voltage required |
Extra functions: Temperature / system monitoring |
Width [mm] |
Type |
---|---|---|---|---|---|---|---|---|
Standard | 1.5 | to 230 | 35 | IL 9017, SL 9017 | ||||
with softstart function | 1.5 | to 230 | 35 | IL 9017/300 | ||||
Standard | 5.5 | 1.5 | to 480 | 45 | BA 9010 | |||
Standard | 11 | 3 | to 480 | 100 | BN 9011 | |||
with softstart function | 7.5 | + | 100 to 480 | + | T, N | 90 | BI 9028/900 | |
Softstarters MINISTART, 2- | |||||||
Function | f. three- motors , 400 V up to [kW] |
Diverse signalling outputs |
Load voltage [V] |
Auxiliary voltage required |
Extra functions: Temperature / system monitoring |
Width [mm] |
Type |
---|---|---|---|---|---|---|---|
with soft coasting and reverse function | 0.75 | + | 200...400 | + | T | 72 | RP9210/300 |
with soft coasting | 110 | + | ... 575 | + | T,N | 98; 145; 202 |
|
with soft coasting | 22 | + | ... 480 | T, N | 45; 52.5 | GF 9016 | |
with soft coasting | 5.5 | 200 ... 480 | + | T | 45 | BA 9019 | |
with soft coasting | 11 | 200 ... 480 | + | T | 90 | BL 9025 | |
with soft coasting | 15 | 200 ... 480 | + | T | 90 | BI 9025 | |
with soft coasting | 7,5 | + | ... 400 | T, N | 45 | ||
with d.c. braking | 15 | + | 200 ... 480 | + | T, N | 90 | BI 9028 |
with d.c. braking and standstill detection |
15 | + | 200 ... 480 | + | T, N | 112.5 | BL9028 /td> |
Softstarters MINISTART, 3- | |||||||
Function | f. three- motors , 400 V up to [kW] |
Diverse signalling outputs |
Load voltage [V] |
Auxiliary voltage required |
Extra functions: Temperature / system monitoring |
Width [mm] |
Type |
---|---|---|---|---|---|---|---|
with softstart function | 800 | 200...525 | + | T, N | 156...750 | GI 9015 | |
with softstart function | 3 | 200...480 | + | T | 45 | BA 9026 | |
with softstart function | 55 | + | ...690 | T | 235; 335 | ||