Relay Modules
Standstill / speed monitoring
Stand-still/speed relays monitor the rotation of drives to generate a control signal at zero speed or when a set speed is exceeded.
Extension modules
- Prewired rail-mounted modules
- Safety category 3 acc. to EN 954-1
- Positively driven output contacts
- Connection monitoring of the proximity switches
These modules have measuring circuits in redundant configuration with 2-channel control by proximity sensors, either as pnp or npn input. The thresholds are either fixed or can be adjusted up to 26000 IPM. Zero-speed monitors can also work without sensors by measuring the remanence voltage of the coasting motor and evaluating it at zero speed.
- Release safety gate interlocks when the stationary condition of a dangerous movement is detected
- Work with opened safeguard devices and reduced speed during the set-up mode of the machine
Speed or stand- | |||||||||||
Function | Cat. / PL acc. to EN 13849- |
SIL CL acc. to EN 62061 * |
1- 2- |
Forcibly guided output contacts, max. |
Indicator contacts |
Nominal voltage | Thermal current Ith max. [A] |
Width [mm] |
Type | ||
---|---|---|---|---|---|---|---|---|---|---|---|
AC/DC | AC | ||||||||||
Speed or stand- |
3 / e | 3 | 1; 2 | 2 NO, 1NC | + | + | 4 | 45 | BH 5932 | ||
Speed monitor | 4 / e | 3 | 1; 2 | 2 NO | 2 SO | + | 8 | 45 | UH 6932 | ||
Speed monitor | 4 / e | 3 | 2 | 4 NO | 2 SO | + | + | 5 | 45 | UH 5947 | |
NO = normally open contact, NC = normally closed contact, SO = semiconductor outputs * Please check state of approval of idividual devices in the latest data sheet. |
Stand- | |||||||||||
Function | Cat. / PL acc. to EN 13849- |
SIL CL acc. to EN 62061 * |
1- 2- |
Forcibly guided output contacts, max. |
Signal contact | Nominal voltage | Thermal current Ith [A] max. |
Measuring- Motor Voltage, max. (V) |
Width [mm] |
Type | |
---|---|---|---|---|---|---|---|---|---|---|---|
DC | AC | ||||||||||
Stand- measurement without sensors |
4 / e | 3 | 2 | 3 NO, 1 NC | 2 SO, 1 NO | + | + | 5 | 690 | 45 | LH 5946 |
NO = normally open contact, NC = normally closed contact, SO = semiconductor outputs * Please check state of approval of idividual devices in the latest data sheet. |